- --Defines CSS-TRAPS-MIB.MIB for SNMP agent extension --Contents: Global Registration Module --CSS OIDs - Enterprise 14748 --Version: 0.10 -- Reviewed & developed by NK -- software engineer -- Computer Support Systems Pty Ltd -- Updates -- Added SafetyNet Series 5 Lite and Micro -- Added SafetyNet Series 5 D40 and D20 -- Added Sentinel 20 -- Added Sentinel 10 -- Completed Tree for SafetyNet Series 5 D20 -- Added SafetyNet Series 5 Combo Version -- Copyright (c) 2011 CSSPL. CSS-TRAPS-MIB DEFINITIONS ::= BEGIN IMPORTS -- Counter, TimeTicks, enterprises,IpAddress, Gauge, Counter FROM RFC1155-SMI DisplayString,sysDescr,sysObjectID,sysUpTime,sysContact,sysName,sysLocation,sysServices,ifNumber,ifIndex, ifDescr,ifType FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 ; computerSupportSystems OBJECT IDENTIFIER ::= { enterprises 14748 } -- assigned by IANA --MODULE-IDENTITY -- -- LAST-UPDATED "201111092300Z" November, 2011 -- ORGANIZATION "Computer Support Systems Pty Ltd" -- CONTACT-INFO -- -- "Nilkamal Kandamudali -- Email: support@csspl.com.au -- nilkamal@y7mail.com" -- -- DESCRIPTION -- "This MIB module defines MIB objects for products of Computer Support Systems." -- -- REVISION "201111092300Z" November , 2011 -- DESCRIPTION "Initial version." trapControl OBJECT IDENTIFIER ::= { computerSupportSystems 4 } trapSource OBJECT IDENTIFIER ::= { trapControl 1} products OBJECT IDENTIFIER ::= { computerSupportSystems 1 } -- products 1-6 are covered in CSS.MIB file safetynetseries5 OBJECT IDENTIFIER ::= { products 7 } safetynetseries5lite OBJECT IDENTIFIER ::= { products 8 } safetynetseries5micro OBJECT IDENTIFIER ::= { products 9 } safetynetseries5D40 OBJECT IDENTIFIER ::= { products 10 } safetynetseries5D20 OBJECT IDENTIFIER ::= { products 11 } safetynetseries5Combo OBJECT IDENTIFIER ::= { products 12 } -- Series 5 objects ss5Readings OBJECT IDENTIFIER ::= { safetynetseries5 1 } ss5Relays OBJECT IDENTIFIER ::= { safetynetseries5 2 } ss5SensorOne OBJECT IDENTIFIER ::= { ss5Readings 1 } ss5SensorTwo OBJECT IDENTIFIER ::= { ss5Readings 2 } ss5SensorThree OBJECT IDENTIFIER ::= { ss5Readings 3 } ss5SensorFour OBJECT IDENTIFIER ::= { ss5Readings 4 } ss5SensorFive OBJECT IDENTIFIER ::= { ss5Readings 5 } ss5SensorSix OBJECT IDENTIFIER ::= { ss5Readings 6 } ss5SensorSeven OBJECT IDENTIFIER ::= { ss5Readings 7 } ss5SensorEight OBJECT IDENTIFIER ::= { ss5Readings 8 } ss5SensorNine OBJECT IDENTIFIER ::= { ss5Readings 9 } ss5SensorTen OBJECT IDENTIFIER ::= { ss5Readings 10 } -- Series 5 Lite objects ss5LiteReadings OBJECT IDENTIFIER ::= { safetynetseries5lite 1 } ss5LiteRelay OBJECT IDENTIFIER ::= { safetynetseries5lite 2 } ss5LiteSensorOne OBJECT IDENTIFIER ::= { ss5LiteReadings 1 } ss5LiteSensorTwo OBJECT IDENTIFIER ::= { ss5LiteReadings 2 } ss5LiteSensorThree OBJECT IDENTIFIER ::= { ss5LiteReadings 3 } ss5LiteSensorFour OBJECT IDENTIFIER ::= { ss5LiteReadings 4 } ss5LiteSensorFive OBJECT IDENTIFIER ::= { ss5LiteReadings 5 } ss5LiteSensorSix OBJECT IDENTIFIER ::= { ss5LiteReadings 6 } -- Series 5 Micro objects ss5MicroReadings OBJECT IDENTIFIER ::= { safetynetseries5micro 1 } ss5MicroSensorOne OBJECT IDENTIFIER ::= { ss5MicroReadings 1 } ss5MicroSensorTwo OBJECT IDENTIFIER ::= { ss5MicroReadings 2 } ss5MicroSensorThree OBJECT IDENTIFIER ::= { ss5MicroReadings 3 } ss5MicroSensorFour OBJECT IDENTIFIER ::= { ss5MicroReadings 4 } -- Series 5D40 objects ss5D40Readings OBJECT IDENTIFIER ::= { safetynetseries5D40 1 } ss5D40Relays OBJECT IDENTIFIER ::= { safetynetseries5D40 2 } ss5D40Sensor01 OBJECT IDENTIFIER ::= { ss5D40Readings 1 } ss5D40Sensor02 OBJECT IDENTIFIER ::= { ss5D40Readings 2 } ss5D40Sensor03 OBJECT IDENTIFIER ::= { ss5D40Readings 3 } ss5D40Sensor04 OBJECT IDENTIFIER ::= { ss5D40Readings 4 } ss5D40Sensor05 OBJECT IDENTIFIER ::= { ss5D40Readings 5 } ss5D40Sensor06 OBJECT IDENTIFIER ::= { ss5D40Readings 6 } ss5D40Sensor07 OBJECT IDENTIFIER ::= { ss5D40Readings 7 } ss5D40Sensor08 OBJECT IDENTIFIER ::= { ss5D40Readings 8 } ss5D40Sensor09 OBJECT IDENTIFIER ::= { ss5D40Readings 9 } ss5D40Sensor10 OBJECT IDENTIFIER ::= { ss5D40Readings 10 } ss5D40Sensor11 OBJECT IDENTIFIER ::= { ss5D40Readings 11 } ss5D40Sensor12 OBJECT IDENTIFIER ::= { ss5D40Readings 12 } ss5D40Sensor13 OBJECT IDENTIFIER ::= { ss5D40Readings 13 } ss5D40Sensor14 OBJECT IDENTIFIER ::= { ss5D40Readings 14 } ss5D40Sensor15 OBJECT IDENTIFIER ::= { ss5D40Readings 15 } ss5D40Sensor16 OBJECT IDENTIFIER ::= { ss5D40Readings 16 } ss5D40Sensor17 OBJECT IDENTIFIER ::= { ss5D40Readings 17 } ss5D40Sensor18 OBJECT IDENTIFIER ::= { ss5D40Readings 18 } ss5D40Sensor19 OBJECT IDENTIFIER ::= { ss5D40Readings 19 } ss5D40Sensor20 OBJECT IDENTIFIER ::= { ss5D40Readings 20 } ss5D40Sensor21 OBJECT IDENTIFIER ::= { ss5D40Readings 21 } ss5D40Sensor22 OBJECT IDENTIFIER ::= { ss5D40Readings 22 } ss5D40Sensor23 OBJECT IDENTIFIER ::= { ss5D40Readings 23 } ss5D40Sensor24 OBJECT IDENTIFIER ::= { ss5D40Readings 24 } ss5D40Sensor25 OBJECT IDENTIFIER ::= { ss5D40Readings 25 } ss5D40Sensor26 OBJECT IDENTIFIER ::= { ss5D40Readings 26 } ss5D40Sensor27 OBJECT IDENTIFIER ::= { ss5D40Readings 27 } ss5D40Sensor28 OBJECT IDENTIFIER ::= { ss5D40Readings 28 } ss5D40Sensor29 OBJECT IDENTIFIER ::= { ss5D40Readings 29 } ss5D40Sensor30 OBJECT IDENTIFIER ::= { ss5D40Readings 30 } ss5D40Sensor31 OBJECT IDENTIFIER ::= { ss5D40Readings 31 } ss5D40Sensor32 OBJECT IDENTIFIER ::= { ss5D40Readings 32 } ss5D40Sensor33 OBJECT IDENTIFIER ::= { ss5D40Readings 33 } ss5D40Sensor34 OBJECT IDENTIFIER ::= { ss5D40Readings 34 } ss5D40Sensor35 OBJECT IDENTIFIER ::= { ss5D40Readings 35 } ss5D40Sensor36 OBJECT IDENTIFIER ::= { ss5D40Readings 36 } ss5D40Sensor37 OBJECT IDENTIFIER ::= { ss5D40Readings 37 } ss5D40Sensor38 OBJECT IDENTIFIER ::= { ss5D40Readings 38 } ss5D40Sensor39 OBJECT IDENTIFIER ::= { ss5D40Readings 39 } ss5D40Sensor40 OBJECT IDENTIFIER ::= { ss5D40Readings 40 } -- Series 5D20 objects ss5D20Readings OBJECT IDENTIFIER ::= { safetynetseries5D20 1 } ss5D20Relays OBJECT IDENTIFIER ::= { safetynetseries5D20 2 } ss5D20Sensor01 OBJECT IDENTIFIER ::= { ss5D20Readings 1 } ss5D20Sensor02 OBJECT IDENTIFIER ::= { ss5D20Readings 2 } ss5D20Sensor03 OBJECT IDENTIFIER ::= { ss5D20Readings 3 } ss5D20Sensor04 OBJECT IDENTIFIER ::= { ss5D20Readings 4 } ss5D20Sensor05 OBJECT IDENTIFIER ::= { ss5D20Readings 5 } ss5D20Sensor06 OBJECT IDENTIFIER ::= { ss5D20Readings 6 } ss5D20Sensor07 OBJECT IDENTIFIER ::= { ss5D20Readings 7 } ss5D20Sensor08 OBJECT IDENTIFIER ::= { ss5D20Readings 8 } ss5D20Sensor09 OBJECT IDENTIFIER ::= { ss5D20Readings 9 } ss5D20Sensor10 OBJECT IDENTIFIER ::= { ss5D20Readings 10 } ss5D20Sensor11 OBJECT IDENTIFIER ::= { ss5D20Readings 11 } ss5D20Sensor12 OBJECT IDENTIFIER ::= { ss5D20Readings 12 } ss5D20Sensor13 OBJECT IDENTIFIER ::= { ss5D20Readings 13 } ss5D20Sensor14 OBJECT IDENTIFIER ::= { ss5D20Readings 14 } ss5D20Sensor15 OBJECT IDENTIFIER ::= { ss5D20Readings 15 } ss5D20Sensor16 OBJECT IDENTIFIER ::= { ss5D20Readings 16 } ss5D20Sensor17 OBJECT IDENTIFIER ::= { ss5D20Readings 17 } ss5D20Sensor18 OBJECT IDENTIFIER ::= { ss5D20Readings 18 } ss5D20Sensor19 OBJECT IDENTIFIER ::= { ss5D20Readings 19 } ss5D20Sensor20 OBJECT IDENTIFIER ::= { ss5D20Readings 20 } -- Series 5 Combo objects ss5ComboReadings OBJECT IDENTIFIER ::= { safetynetseries5Combo 1 } ss5ComboRelays OBJECT IDENTIFIER ::= { safetynetseries5Combo 2 } ss5ComboUniversal01 OBJECT IDENTIFIER ::= { ss5ComboReadings 1 } ss5ComboUniversal02 OBJECT IDENTIFIER ::= { ss5ComboReadings 2 } ss5ComboUniversal03 OBJECT IDENTIFIER ::= { ss5ComboReadings 3 } ss5ComboUniversal04 OBJECT IDENTIFIER ::= { ss5ComboReadings 4 } ss5ComboUniversal05 OBJECT IDENTIFIER ::= { ss5ComboReadings 5 } ss5ComboUniversal06 OBJECT IDENTIFIER ::= { ss5ComboReadings 6 } ss5ComboDigital01 OBJECT IDENTIFIER ::= { ss5ComboReadings 7 } ss5ComboDigital02 OBJECT IDENTIFIER ::= { ss5ComboReadings 8 } ss5ComboDigital03 OBJECT IDENTIFIER ::= { ss5ComboReadings 9 } ss5ComboDigital04 OBJECT IDENTIFIER ::= { ss5ComboReadings 10 } ss5ComboDigital05 OBJECT IDENTIFIER ::= { ss5ComboReadings 11 } ss5ComboDigital06 OBJECT IDENTIFIER ::= { ss5ComboReadings 12 } ss5ComboDigital07 OBJECT IDENTIFIER ::= { ss5ComboReadings 13 } ss5ComboDigital08 OBJECT IDENTIFIER ::= { ss5ComboReadings 14 } ss5ComboDigital09 OBJECT IDENTIFIER ::= { ss5ComboReadings 15 } ss5ComboDigital10 OBJECT IDENTIFIER ::= { ss5ComboReadings 16 } ss5ComboDigital11 OBJECT IDENTIFIER ::= { ss5ComboReadings 17 } ss5ComboDigital12 OBJECT IDENTIFIER ::= { ss5ComboReadings 18 } ss5ComboDigital13 OBJECT IDENTIFIER ::= { ss5ComboReadings 19 } ss5ComboDigital14 OBJECT IDENTIFIER ::= { ss5ComboReadings 20 } ss5ComboDigital15 OBJECT IDENTIFIER ::= { ss5ComboReadings 21 } ss5ComboDigital16 OBJECT IDENTIFIER ::= { ss5ComboReadings 22 } ss5ComboDigital17 OBJECT IDENTIFIER ::= { ss5ComboReadings 23 } ss5ComboDigital18 OBJECT IDENTIFIER ::= { ss5ComboReadings 24 } ss5ComboDigital19 OBJECT IDENTIFIER ::= { ss5ComboReadings 25 } ss5ComboDigital20 OBJECT IDENTIFIER ::= { ss5ComboReadings 26 } oemProducts OBJECT IDENTIFIER ::= { computerSupportSystems 2 } -- oemProducts 1-6 are covered in CSS.MIB file sentinel20Way OBJECT IDENTIFIER ::= { oemProducts 7 } sentinel10Way OBJECT IDENTIFIER ::= { oemProducts 8 } -- Sentinel 20 objects sentinel20_outletReading OBJECT IDENTIFIER ::= { sentinel20Way 1 } sentinel20_sensorReading OBJECT IDENTIFIER ::= { sentinel20Way 2 } sentinel10_outletReading OBJECT IDENTIFIER ::= { sentinel10Way 1 } sentinel10_sensorReading OBJECT IDENTIFIER ::= { sentinel10Way 2 } ss5SensorOneType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorOne 1 } ss5SensorOneName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorOne 2 } ss5SensorOneReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor one reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorOne 3 } ss5SensorTwoType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorTwo 1 } ss5SensorTwoName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorTwo 2 } ss5SensorTwoReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor two reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorTwo 3 } ss5SensorThreeType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorThree 1 } ss5SensorThreeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorThree 2 } ss5SensorThreeReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor three reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorThree 3 } ss5SensorFourType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorFour 1 } ss5SensorFourName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorFour 2 } ss5SensorFourReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor four reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorFour 3 } ss5SensorFiveType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorFive 1 } ss5SensorFiveName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorFive 2 } ss5SensorFiveReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor five reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorFive 3 } ss5SensorSixType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorSix 1 } ss5SensorSixName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorSix 2 } ss5SensorSixReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor six reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorSix 3 } ss5SensorSevenType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorSeven 1 } ss5SensorSevenName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorSeven 2 } ss5SensorSevenReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor seven reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorSeven 3 } ss5SensorEightType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorEight 1 } ss5SensorEightName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorEight 2 } ss5SensorEightReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor eight reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorEight 3 } ss5SensorNineType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorNine 1 } ss5SensorNineName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorNine 2 } ss5SensorNineReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor nine reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorNine 3 } ss5SensorTenType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5SensorTen 1 } ss5SensorTenName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5SensorTen 2 } ss5SensorTenReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor ten reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5SensorTen 3 } ss5IpMonitoringReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 IP Monitoring Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5Readings 11 } ss5LowBatteryReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Low Battery. 1 = alarm condition 0 = not in alarm condition" ::= { ss5Readings 12 } ss5MainsFailureReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Mains Failure Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5Readings 13 } ss5FaultySensorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Faulty Sensor(s) Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5Readings 14 } ss5DialToneOrSIMErrorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Dial Tone Alarm for PSTN Modem Version. SafetyNet Series 5 GSM SIM Card Error Alarm for GSM Modem Version. 1 = alarm condition 0 = not in alarm condition" ::= { ss5Readings 15 } ss5RelayOne OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Relay One Status. 0 = Relay active 1 = Relay inactive" ::= { ss5Relays 1 } ss5RelayTwo OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Relay Two Status. 0 = Relay active 1 = Relay inactive" ::= { ss5Relays 2 } -- Series 5 Lite begins here ss5LiteSensorOneType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5LiteSensorOne 1 } ss5LiteSensorOneName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Lite" ::= { ss5LiteSensorOne 2 } ss5LiteSensorOneReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite sensor one reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5LiteSensorOne 3 } ss5LiteSensorTwoType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5LiteSensorTwo 1 } ss5LiteSensorTwoName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Lite" ::= { ss5LiteSensorTwo 2 } ss5LiteSensorTwoReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite sensor two reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5LiteSensorTwo 3 } ss5LiteSensorThreeType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5LiteSensorThree 1 } ss5LiteSensorThreeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Lite" ::= { ss5LiteSensorThree 2 } ss5LiteSensorThreeReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite sensor three reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5LiteSensorThree 3 } ss5LiteSensorFourType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5LiteSensorFour 1 } ss5LiteSensorFourName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Lite" ::= { ss5LiteSensorFour 2 } ss5LiteSensorFourReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite sensor four reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5LiteSensorFour 3 } ss5LiteSensorFiveType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5LiteSensorFive 1 } ss5LiteSensorFiveName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Lite" ::= { ss5LiteSensorFive 2 } ss5LiteSensorFiveReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite sensor five reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5LiteSensorFive 3 } ss5LiteSensorSixType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5LiteSensorSix 1 } ss5LiteSensorSixName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Lite" ::= { ss5LiteSensorSix 2 } ss5LiteSensorSixReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite sensor six reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5LiteSensorSix 3 } ss5LiteIpMonitoringReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite IP Monitoring Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5LiteReadings 7 } ss5LiteLowBatteryReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite Low Battery. 1 = alarm condition 0 = not in alarm condition" ::= { ss5LiteReadings 8 } ss5LiteMainsFailureReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite Mains Failure Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5LiteReadings 9 } ss5LiteFaultySensorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite Faulty Sensor(s) Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5LiteReadings 10 } ss5LiteDialToneOrSIMErrorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite Dial Tone Alarm for PSTN Modem Version. SafetyNet Series 5 Lite GSM SIM Card Error Alarm for GSM Modem Version. 1 = alarm condition 0 = not in alarm condition" ::= { ss5LiteReadings 11 } ss5LiteRelay01 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Lite Relay Status. 0 = Relay active 1 = Relay inactive" ::= { ss5LiteRelay 1 } -- Series 5 Micro begins here ss5MicroSensorOneType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5MicroSensorOne 1 } ss5MicroSensorOneName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Micro" ::= { ss5MicroSensorOne 2 } ss5MicroSensorOneReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro sensor one reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5MicroSensorOne 3 } ss5MicroSensorTwoType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5MicroSensorTwo 1 } ss5MicroSensorTwoName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Micro" ::= { ss5MicroSensorTwo 2 } ss5MicroSensorTwoReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro sensor two reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5MicroSensorTwo 3 } ss5MicroSensorThreeType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5MicroSensorThree 1 } ss5MicroSensorThreeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Micro" ::= { ss5MicroSensorThree 2 } ss5MicroSensorThreeReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro sensor three reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5MicroSensorThree 3 } ss5MicroSensorFourType OBJECT-TYPE SYNTAX INTEGER(0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5MicroSensorFour 1 } ss5MicroSensorFourName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Micro" ::= { ss5MicroSensorFour 2 } ss5MicroSensorFourReading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro sensor four reading. If sensor is Digital 1 = sensor in alarm condition 0 = sensor not in alarm condition if sensor is Analogue use multiplier 0.1 for actual reading" ::= { ss5MicroSensorFour 3 } ss5MicroIpMonitoringReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro IP Monitoring Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5MicroReadings 5 } ss5MicroLowBatteryReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro Low Battery. 1 = alarm condition 0 = not in alarm condition" ::= { ss5MicroReadings 6 } ss5MicroMainsFailureReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro Mains Failure Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5MicroReadings 7 } ss5MicroFaultySensorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro Faulty Sensor(s) Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5MicroReadings 8 } ss5MicroDialToneOrSIMErrorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Micro Dial Tone Alarm for PSTN Modem Version. SafetyNet Series 5 Micro GSM SIM Card Error Alarm for GSM Modem Version. 1 = alarm condition 0 = not in alarm condition" ::= { ss5MicroReadings 9} --SafetyNet Series 5 D40 expansion. ss5D40Sensor01Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor01 1 } ss5D40Sensor01Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor01 2 } ss5D40Sensor01Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor01 3 } ss5D40Sensor02Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor02 1 } ss5D40Sensor02Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor02 2 } ss5D40Sensor02Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor02 3 } ss5D40Sensor03Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor03 1 } ss5D40Sensor03Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor03 2 } ss5D40Sensor03Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor03 3 } ss5D40Sensor04Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor04 1 } ss5D40Sensor04Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor04 2 } ss5D40Sensor04Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor04 3 } ss5D40Sensor05Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor05 1 } ss5D40Sensor05Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor05 2 } ss5D40Sensor05Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor05 3 } ss5D40Sensor06Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor06 1 } ss5D40Sensor06Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor06 2 } ss5D40Sensor06Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor06 3 } ss5D40Sensor07Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor07 1 } ss5D40Sensor07Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor07 2 } ss5D40Sensor07Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor07 3 } ss5D40Sensor08Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor08 1 } ss5D40Sensor08Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor08 2 } ss5D40Sensor08Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor08 3 } ss5D40Sensor09Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor09 1 } ss5D40Sensor09Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor09 2 } ss5D40Sensor09Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor09 3 } ss5D40Sensor10Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor10 1 } ss5D40Sensor10Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor10 2 } ss5D40Sensor10Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor10 3 } ss5D40Sensor11Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor11 1 } ss5D40Sensor11Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor11 2 } ss5D40Sensor11Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor11 3 } ss5D40Sensor12Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor12 1 } ss5D40Sensor12Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor12 2 } ss5D40Sensor12Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor12 3 } ss5D40Sensor13Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor13 1 } ss5D40Sensor13Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor13 2 } ss5D40Sensor13Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor13 3 } ss5D40Sensor14Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor14 1 } ss5D40Sensor14Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor14 2 } ss5D40Sensor14Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor14 3 } ss5D40Sensor15Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor15 1 } ss5D40Sensor15Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor15 2 } ss5D40Sensor15Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor15 3 } ss5D40Sensor16Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor16 1 } ss5D40Sensor16Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor16 2 } ss5D40Sensor16Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor16 3 } ss5D40Sensor17Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor17 1 } ss5D40Sensor17Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor17 2 } ss5D40Sensor17Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor17 3 } ss5D40Sensor18Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor18 1 } ss5D40Sensor18Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor18 2 } ss5D40Sensor18Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor18 3 } ss5D40Sensor19Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor19 1 } ss5D40Sensor19Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor19 2 } ss5D40Sensor19Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor19 3 } ss5D40Sensor20Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor20 1 } ss5D40Sensor20Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor20 2 } ss5D40Sensor20Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor20 3 } ss5D40Sensor21Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor21 1 } ss5D40Sensor21Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor21 2 } ss5D40Sensor21Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor21 3 } ss5D40Sensor22Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor22 1 } ss5D40Sensor22Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor22 2 } ss5D40Sensor22Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor22 3 } ss5D40Sensor23Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor23 1 } ss5D40Sensor23Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor23 2 } ss5D40Sensor23Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor23 3 } ss5D40Sensor24Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor24 1 } ss5D40Sensor24Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor24 2 } ss5D40Sensor24Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor24 3 } ss5D40Sensor25Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor25 1 } ss5D40Sensor25Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor25 2 } ss5D40Sensor25Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor25 3 } ss5D40Sensor26Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor26 1 } ss5D40Sensor26Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor26 2 } ss5D40Sensor26Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor26 3 } ss5D40Sensor27Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor27 1 } ss5D40Sensor27Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor27 2 } ss5D40Sensor27Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor27 3 } ss5D40Sensor28Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor28 1 } ss5D40Sensor28Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor28 2 } ss5D40Sensor28Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor28 3 } ss5D40Sensor29Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor29 1 } ss5D40Sensor29Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor29 2 } ss5D40Sensor29Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor29 3 } ss5D40Sensor30Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor30 1 } ss5D40Sensor30Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor30 2 } ss5D40Sensor30Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor30 3 } ss5D40Sensor31Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor31 1 } ss5D40Sensor31Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor31 2 } ss5D40Sensor31Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor31 3 } ss5D40Sensor32Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor32 1 } ss5D40Sensor32Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor32 2 } ss5D40Sensor32Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor32 3 } ss5D40Sensor33Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor33 1 } ss5D40Sensor33Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor33 2 } ss5D40Sensor33Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor33 3 } ss5D40Sensor34Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor34 1 } ss5D40Sensor34Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor34 2 } ss5D40Sensor34Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor34 3 } ss5D40Sensor35Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor35 1 } ss5D40Sensor35Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor35 2 } ss5D40Sensor35Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor35 3 } ss5D40Sensor36Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor36 1 } ss5D40Sensor36Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor36 2 } ss5D40Sensor36Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor36 3 } ss5D40Sensor37Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor37 1 } ss5D40Sensor37Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor37 2 } ss5D40Sensor37Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor37 3 } ss5D40Sensor38Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor38 1 } ss5D40Sensor38Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor38 2 } ss5D40Sensor38Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor38 3 } ss5D40Sensor39Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor39 1 } ss5D40Sensor39Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor39 2 } ss5D40Sensor39Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor39 3 } ss5D40Sensor40Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D40Sensor40 1 } ss5D40Sensor40Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D40Sensor40 2 } ss5D40Sensor40Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D40Sensor40 3 } ss5D40IpMonitoringReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 IP Monitoring Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D40Readings 41 } ss5D40LowBatteryReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Low Battery. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D40Readings 42 } ss5D40MainsFailureReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Mains Failure Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D40Readings 43 } ss5D40DialToneOrSIMErrorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Dial Tone Alarm for PSTN Modem Version. SafetyNet Series 5 GSM SIM Card Error Alarm for GSM Modem Version. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D40Readings 45 } ss5D40RelayOne OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 D40 Relay One Status. 0 = Relay active 1 = Relay inactive" ::= { ss5D40Relays 1 } ss5D40RelayTwo OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 D40 Relay Two Status. 0 = Relay active 1 = Relay inactive" ::= { ss5D40Relays 2 } --SafetyNet Series 5 D20 expansion. ss5D20Sensor01Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor01 1 } ss5D20Sensor01Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor01 2 } ss5D20Sensor01Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor01 3 } ss5D20Sensor02Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor02 1 } ss5D20Sensor02Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor02 2 } ss5D20Sensor02Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor02 3 } ss5D20Sensor03Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor03 1 } ss5D20Sensor03Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor03 2 } ss5D20Sensor03Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor03 3 } ss5D20Sensor04Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor04 1 } ss5D20Sensor04Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor04 2 } ss5D20Sensor04Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor04 3 } ss5D20Sensor05Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor05 1 } ss5D20Sensor05Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor05 2 } ss5D20Sensor05Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor05 3 } ss5D20Sensor06Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor06 1 } ss5D20Sensor06Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor06 2 } ss5D20Sensor06Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor06 3 } ss5D20Sensor07Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor07 1 } ss5D20Sensor07Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor07 2 } ss5D20Sensor07Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor07 3 } ss5D20Sensor08Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor08 1 } ss5D20Sensor08Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor08 2 } ss5D20Sensor08Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor08 3 } ss5D20Sensor09Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor09 1 } ss5D20Sensor09Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor09 2 } ss5D20Sensor09Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor09 3 } ss5D20Sensor10Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor10 1 } ss5D20Sensor10Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor10 2 } ss5D20Sensor10Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor10 3 } ss5D20Sensor11Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor11 1 } ss5D20Sensor11Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor11 2 } ss5D20Sensor11Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor11 3 } ss5D20Sensor12Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor12 1 } ss5D20Sensor12Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor12 2 } ss5D20Sensor12Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor12 3 } ss5D20Sensor13Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor13 1 } ss5D20Sensor13Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor13 2 } ss5D20Sensor13Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor13 3 } ss5D20Sensor14Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor14 1 } ss5D20Sensor14Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor14 2 } ss5D20Sensor14Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor14 3 } ss5D20Sensor15Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor15 1 } ss5D20Sensor15Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor15 2 } ss5D20Sensor15Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor15 3 } ss5D20Sensor16Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor16 1 } ss5D20Sensor16Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor16 2 } ss5D20Sensor16Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor16 3 } ss5D20Sensor17Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor17 1 } ss5D20Sensor17Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor17 2 } ss5D20Sensor17Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor17 3 } ss5D20Sensor18Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor18 1 } ss5D20Sensor18Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor18 2 } ss5D20Sensor18Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor18 3 } ss5D20Sensor19Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor19 1 } ss5D20Sensor19Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor19 2 } ss5D20Sensor19Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor19 3 } ss5D20Sensor20Type OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Digital 1 = Fluid 2 = Security 3 = Zoned Security 4 = Smoke" ::= { ss5D20Sensor20 1 } ss5D20Sensor20Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5" ::= { ss5D20Sensor20 2 } ss5D20Sensor20Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 sensor reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5D20Sensor20 3 } ss5D20IpMonitoringReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 IP Monitoring Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D20Readings 21 } ss5D20LowBatteryReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Low Battery. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D20Readings 22 } ss5D20MainsFailureReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Mains Failure Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D20Readings 23 } ss5D20DialToneOrSIMErrorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Dial Tone Alarm for PSTN Modem Version. SafetyNet Series 5 GSM SIM Card Error Alarm for GSM Modem Version. 1 = alarm condition 0 = not in alarm condition" ::= { ss5D20Readings 25 } ss5D20Relay OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 D20 Relay Status. 0 = Relay active 1 = Relay inactive" ::= { ss5D20Relays 1 } -- SafetyNet Series 5 Combo description ss5ComboUniversal01Type OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid" ::= { ss5ComboUniversal01 1 } ss5ComboUniversal01Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboUniversal01 2 } ss5ComboUniversal01Reading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo universal sensor one reading. If sensor is Analogue use multiplier 0.1 for actual reading If sensor is Smoke or Fluid, 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboUniversal01 3 } ss5ComboUniversal02Type OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid" ::= { ss5ComboUniversal02 1 } ss5ComboUniversal02Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboUniversal02 2 } ss5ComboUniversal02Reading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 universal sensor two reading. If sensor is Analogue use multiplier 0.1 for actual reading If sensor is Smoke or Fluid, 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboUniversal02 3 } ss5ComboUniversal03Type OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid" ::= { ss5ComboUniversal03 1 } ss5ComboUniversal03Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboUniversal03 2 } ss5ComboUniversal03Reading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 universal sensor three reading. If sensor is Analogue use multiplier 0.1 for actual reading If sensor is Smoke or Fluid, 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboUniversal03 3 } ss5ComboUniversal04Type OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid" ::= { ss5ComboUniversal04 1 } ss5ComboUniversal04Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboUniversal04 2 } ss5ComboUniversal04Reading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 universal sensor four reading. If sensor is Analogue use multiplier 0.1 for actual reading If sensor is Smoke or Fluid, 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboUniversal04 3 } ss5ComboUniversal05Type OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid" ::= { ss5ComboUniversal05 1 } ss5ComboUniversal05Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboUniversal05 2 } ss5ComboUniversal05Reading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 universal sensor five reading. If sensor is Analogue use multiplier 0.1 for actual reading If sensor is Smoke or Fluid, 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboUniversal05 3 } ss5ComboUniversal06Type OBJECT-TYPE SYNTAX INTEGER(0..7) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 0 = Temperature 1 = Humidity 2 = DC Voltage 3 = AC Voltage 4 = Temperature/Humidity Dual (Associated Temperature Sensor) 5 = Smoke 6 = Fluid" ::= { ss5ComboUniversal06 1 } ss5ComboUniversal06Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboUniversal06 2 } ss5ComboUniversal06Reading OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 universal sensor six reading. If sensor is Analogue use multiplier 0.1 for actual reading If sensor is Smoke or Fluid, 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboUniversal06 3 } ss5ComboDigital01Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital01 1 } ss5ComboDigital01Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital01 2 } ss5ComboDigital01Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 01 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital01 3 } ss5ComboDigital02Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital02 1 } ss5ComboDigital02Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital02 2 } ss5ComboDigital02Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 02 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital02 3 } ss5ComboDigital03Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital03 1 } ss5ComboDigital03Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital03 2 } ss5ComboDigital03Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 03 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital03 3 } ss5ComboDigital04Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital04 1 } ss5ComboDigital04Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital04 2 } ss5ComboDigital04Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 04 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital04 3 } ss5ComboDigital05Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital05 1 } ss5ComboDigital05Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital05 2 } ss5ComboDigital05Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 05 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital05 3 } ss5ComboDigital06Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital06 1 } ss5ComboDigital06Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital06 2 } ss5ComboDigital06Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 06 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital06 3 } ss5ComboDigital07Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital07 1 } ss5ComboDigital07Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital07 2 } ss5ComboDigital07Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 07 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital07 3 } ss5ComboDigital08Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital08 1 } ss5ComboDigital08Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital08 2 } ss5ComboDigital08Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 08 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital08 3 } ss5ComboDigital09Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital09 1 } ss5ComboDigital09Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital09 2 } ss5ComboDigital09Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 09 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital09 3 } ss5ComboDigital10Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital10 1 } ss5ComboDigital10Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital10 2 } ss5ComboDigital10Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 10 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital10 3 } ss5ComboDigital11Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital11 1 } ss5ComboDigital11Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital11 2 } ss5ComboDigital11Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 11 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital11 3 } ss5ComboDigital12Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital12 1 } ss5ComboDigital12Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital12 2 } ss5ComboDigital12Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 12 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital12 3 } ss5ComboDigital13Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital13 1 } ss5ComboDigital13Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital13 2 } ss5ComboDigital13Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 13 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital13 3 } ss5ComboDigital14Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital14 1 } ss5ComboDigital14Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital14 2 } ss5ComboDigital14Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 14 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital14 3 } ss5ComboDigital15Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital15 1 } ss5ComboDigital15Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital15 2 } ss5ComboDigital15Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 15 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital15 3 } ss5ComboDigital16Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital16 1 } ss5ComboDigital16Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital16 2 } ss5ComboDigital16Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 16 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital16 3 } ss5ComboDigital17Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital17 1 } ss5ComboDigital17Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital17 2 } ss5ComboDigital17Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 17 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital17 3 } ss5ComboDigital18Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital18 1 } ss5ComboDigital18Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital18 2 } ss5ComboDigital18Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 18 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital18 3 } ss5ComboDigital19Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital19 1 } ss5ComboDigital19Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital19 2 } ss5ComboDigital19Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 19 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital19 3 } ss5ComboDigital20Type OBJECT-TYPE SYNTAX INTEGER(5..9) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input type 5 = Smoke 6 = Fluid 7 = Digital 8 = Zoned Security 9 = Security" ::= { ss5ComboDigital20 1 } ss5ComboDigital20Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Name of SafetyNet Series 5 Combo" ::= { ss5ComboDigital20 2 } ss5ComboDigital20Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo digital sensor 20 reading. 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { ss5ComboDigital20 3 } ss5ComboIpMonitoringReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo IP Monitoring Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5ComboReadings 27 } ss5ComboLowBatteryReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo Low Battery. 1 = alarm condition 0 = not in alarm condition" ::= { ss5ComboReadings 28 } ss5ComboMainsFailureReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo Mains Failure Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5ComboReadings 29 } ss5ComboFaultySensorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo Faulty Sensor(s) Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5ComboReadings 30 } ss5ComboSIMErrorReading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo SIM Card Error Alarm. 1 = alarm condition 0 = not in alarm condition" ::= { ss5ComboReadings 31 } ss5ComboRelayOne OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo Relay One Status. 0 = Relay active 1 = Relay inactive" ::= { ss5ComboRelays 1 } ss5ComboRelayTwo OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "SafetyNet Series 5 Combo Relay Two Status. 0 = Relay active 1 = Relay inactive" ::= { ss5ComboRelays 2 } -- OEM product description sentinel20_outlet1 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 1 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 1 } sentinel20_outlet2 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 2 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 2 } sentinel20_outlet3 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 3 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 3 } sentinel20_outlet4 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 4 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 4 } sentinel20_outlet5 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 5 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 5 } sentinel20_outlet6 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 6 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 6 } sentinel20_outlet7 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 7 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 7 } sentinel20_outlet8 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 8 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 8 } sentinel20_outlet9 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 9 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 9 } sentinel20_outlet10 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 10 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 10 } sentinel20_outlet11 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 11 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 11 } sentinel20_outlet12 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 12 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 12 } sentinel20_outlet13 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 13 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 13 } sentinel20_outlet14 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 14 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 14 } sentinel20_outlet15 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 15 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 15 } sentinel20_outlet16 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 16 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 16 } sentinel20_outlet17 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 17 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 17 } sentinel20_outlet18 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 18 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 18 } sentinel20_outlet19 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 19 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 19 } sentinel20_outlet20 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 20 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel20_outletReading 20 } -- sentinel20_sensorReading tree sentinel20_currentConsumption OBJECT IDENTIFIER ::= { sentinel20_sensorReading 1 } sentinel20_temperature OBJECT IDENTIFIER ::= { sentinel20_sensorReading 2 } sentinel20_humidity OBJECT IDENTIFIER ::= { sentinel20_sensorReading 3 } sentinel20_digital_1 OBJECT IDENTIFIER ::= { sentinel20_sensorReading 4 } sentinel20_digital_2 OBJECT IDENTIFIER ::= { sentinel20_sensorReading 5 } sentinel20_currentConsumption_Reading OBJECT-TYPE SYNTAX INTEGER(0..40000) ACCESS read-only STATUS mandatory DESCRIPTION "Total current consumption - Sentinel 20 This value is in milli amperes. To convert to Amperes, multiply by 1000" ::= { sentinel20_currentConsumption 1 } sentinel20_currentConsumption_Status OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for Current Load Sensor 0 = level OK 1 = level at warning level 2 = level at alarm level 3 = level at critical level" ::= { sentinel20_currentConsumption 2 } sentinel20_temperature_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Sensor Name - Sentinel 20" ::= { sentinel20_temperature 1 } sentinel20_temperature_Reading OBJECT-TYPE SYNTAX INTEGER(-20..120) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Sensor Reading - Sentinel 20 Use multiplier 0.1 for actual reading" ::= { sentinel20_temperature 2 } sentinel20_temperature_Status OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for Temperature Sensor 0 = level OK 1 = level at high warning level 2 = level at high alarm level 3 = level at high shutdown level 4 = level at low warning level 5 = level at low alarm level 6 = level at low shutdown level" ::= { sentinel20_temperature 3 } sentinel20_humidity_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Sensor Name - Sentinel 20" ::= { sentinel20_humidity 1 } sentinel20_humidity_Reading OBJECT-TYPE SYNTAX INTEGER(-20..120) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Sensor Reading - Sentinel 20 Use multiplier 0.1 for actual reading" ::= { sentinel20_humidity 2 } sentinel20_humidity_Status OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for Humidity Sensor 0 = level OK 1 = level at high warning level 2 = level at high alarm level 3 = level at high shutdown level 4 = level at low warning level 5 = level at low alarm level 6 = level at low shutdown level" ::= { sentinel20_humidity 3 } sentinel20_digital_1_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor One Name - Sentinel 20" ::= { sentinel20_digital_1 1 } sentinel20_digital_1_Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor One Reading - Sentinel 20 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { sentinel20_digital_1 2 } sentinel20_digital_2_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor Two Name - Sentinel 20" ::= { sentinel20_digital_2 1 } sentinel20_digital_2_Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor Two Reading - Sentinel 20 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { sentinel20_digital_2 2 } -- Sentinet 10 OIDs sentinel10_outlet1 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 1 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 1 } sentinel10_outlet2 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 2 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 2 } sentinel10_outlet3 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 3 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 3 } sentinel10_outlet4 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 4 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 4 } sentinel10_outlet5 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 5 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 5 } sentinel10_outlet6 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 6 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 6 } sentinel10_outlet7 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 7 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 7 } sentinel10_outlet8 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 8 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 8 } sentinel10_outlet9 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 9 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 9 } sentinel10_outlet10 OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Sentinel Outlet 10 Status 00 = OUTLET OFF 01 = OUTLET ON 02 = OUTLET REBOOTING 03 = STARTING UP " ::= { sentinel10_outletReading 10 } -- sentinel10_sensorReading tree sentinel10_currentConsumption OBJECT IDENTIFIER ::= { sentinel10_sensorReading 1 } sentinel10_temperature OBJECT IDENTIFIER ::= { sentinel10_sensorReading 2 } sentinel10_humidity OBJECT IDENTIFIER ::= { sentinel10_sensorReading 3 } sentinel10_digital_1 OBJECT IDENTIFIER ::= { sentinel10_sensorReading 4 } sentinel10_digital_2 OBJECT IDENTIFIER ::= { sentinel10_sensorReading 5 } sentinel10_currentConsumption_Reading OBJECT-TYPE SYNTAX INTEGER(0..40000) ACCESS read-only STATUS mandatory DESCRIPTION "Total current consumption - Sentinel 20 This value is in milli amperes. To convert to Amperes, multiply by 1000" ::= { sentinel10_currentConsumption 1 } sentinel10_currentConsumption_Status OBJECT-TYPE SYNTAX INTEGER(0..4) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for Current Load Sensor 0 = level OK 1 = level at warning level 2 = level at alarm level 3 = level at critical level" ::= { sentinel10_currentConsumption 2 } sentinel10_temperature_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Sensor Name - Sentinel 20" ::= { sentinel10_temperature 1 } sentinel10_temperature_Reading OBJECT-TYPE SYNTAX INTEGER(-20..120) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Sensor Reading - Sentinel 20 Use multiplier 0.1 for actual reading" ::= { sentinel10_temperature 2 } sentinel10_temperature_Status OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for Temperature Sensor 0 = level OK 1 = level at high warning level 2 = level at high alarm level 3 = level at high shutdown level 4 = level at low warning level 5 = level at low alarm level 6 = level at low shutdown level" ::= { sentinel10_temperature 3 } sentinel10_humidity_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Sensor Name - Sentinel 20" ::= { sentinel10_humidity 1 } sentinel10_humidity_Reading OBJECT-TYPE SYNTAX INTEGER(-20..120) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Sensor Reading - Sentinel 20 Use multiplier 0.1 for actual reading" ::= { sentinel10_humidity 2 } sentinel10_humidity_Status OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for Humidity Sensor 0 = level OK 1 = level at high warning level 2 = level at high alarm level 3 = level at high shutdown level 4 = level at low warning level 5 = level at low alarm level 6 = level at low shutdown level" ::= { sentinel10_humidity 3 } sentinel10_digital_1_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor One Name - Sentinel 20" ::= { sentinel10_digital_1 1 } sentinel10_digital_1_Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor One Reading - Sentinel 20 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { sentinel10_digital_1 2 } sentinel10_digital_2_Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..42)) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor Two Name - Sentinel 20" ::= { sentinel10_digital_2 1 } sentinel10_digital_2_Reading OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Digital Sensor Two Reading - Sentinel 20 1 = sensor in alarm condition 0 = sensor not in alarm condition" ::= { sentinel10_digital_2 2 } -- Trap Control Tree defined here trapDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "Textual message giving more detailed information on alarms/alerts/notifications on SNMP agent" ::= { trapControl 2 } sensorID OBJECT-TYPE SYNTAX INTEGER(0..26) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for the sensor/input in alarm or alarm clearance 0 = first sensor 1 = second sensor ... n = sensor n+1 For product safetynetseries5Combo: 0 to 5 = Universal Sensors 1 to 6 6 to 25 = Digital Sensors 1 to 20 " ::= { trapControl 3 } sensorValue OBJECT-TYPE SYNTAX INTEGER(-200..1200) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor reading for analogue type sensors (use multiplier 0.1 for actual reading)" ::= { trapControl 4 } currentConsumption OBJECT-TYPE SYNTAX INTEGER(0..40000) ACCESS read-only STATUS mandatory DESCRIPTION "Current Consumption Sensor reading. Value is in milli-Amperes. For value in Amperes, multiply by 1000" ::= { trapControl 5 } outletID OBJECT-TYPE SYNTAX INTEGER(0..20) ACCESS read-only STATUS mandatory DESCRIPTION "Provides an identification for outlet, where an event occurred. 0 = first outlet 1 = second outlet ... n = outlet n+1 " ::= { trapControl 6 } outletName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..33)) ACCESS read-only STATUS mandatory DESCRIPTION "Outlet name where event occurred" ::= { trapControl 7 } -- **************************************************************************** -- **************************************************************************** -- -- Traps from trapControl: -- clearTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID alarm is cleared. Sensor reading is sensorValue. " ::= 20 warningHighTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID has triggered a high warning. Sensor reading is sensorValue" ::= 21 warningLowTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID has triggered a low warning. Sensor reading is sensorValue" ::= 22 alarmHighTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue} DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID has triggered a high alarm. Sensor reading is sensorValue" ::= 23 alarmLowTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID has triggered a low alarm. Sensor reading is sensorValue" ::= 24 clearHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Humidity sensor sensorID alarm is cleared. Sensor reading is sensorValue" ::= 25 warningHighHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Humidity sensor sensorID has triggered a high warning. Sensor reading is sensorValue" ::= 26 warningLowHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Humidity sensor sensorID has triggered a low warning. Sensor reading is sensorValue" ::= 27 alarmHighHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue} DESCRIPTION "Trap origin is from trapSource. Humidity sensor sensorID has triggered a high alarm. Sensor reading is sensorValue" ::= 28 alarmLowHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Humidity sensor sensorID has triggered a low alarm. Sensor reading is sensorValue" ::= 29 clearDCVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. DC Voltage sensor sensorID alarm is cleared. Sensor reading is sensorValue" ::= 30 warningHighDCVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. DC Voltage sensor sensorID has triggered a high warning. Sensor reading is sensorValue" ::= 31 warningLowDCVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. DC Voltage sensor sensorID has triggered a low warning. Sensor reading is sensorValue" ::= 32 alarmHighDCVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue} DESCRIPTION "Trap origin is from trapSource. DC Voltage sensor sensorID has triggered a high alarm. Sensor reading is sensorValue" ::= 33 alarmLowDCVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. DC Voltage sensor sensorID has triggered a low alarm. Sensor reading is sensorValue" ::= 34 alarmSmokeSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Smoke sensor sensorID has triggered an alarm" ::= 35 clearSmokeSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Smoke sensor sensorID has cleared an alarm" ::= 36 alarmFluidSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Fluid sensor sensorID has triggered an alarm" ::= 37 clearFluidSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Fluid sensor sensorID has cleared an alarm" ::= 38 alarmDigitalSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Digital sensor sensorID has triggered an alarm" ::= 39 clearDigitalSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Digital sensor sensorID has cleared an alarm" ::= 40 alarmZonedSecuritySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Zoned Security sensor sensorID has triggered an alarm" ::= 41 clearZonedSecuritySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Zoned Security sensor sensorID has cleared an alarm" ::= 42 alarmSecuritySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Security sensor sensorID has triggered an alarm" ::= 43 clearSecuritySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID } DESCRIPTION "Trap origin is from trapSource. Security sensor sensorID has cleared an alarm" ::= 44 alarmIPMonitoring TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. IP monitoring alarm has been triggered" ::= 45 clearIPMonitoring TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. IP monitoring alarm has been cleared" ::= 46 alarmLowBattery TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Low battery alarm has been triggered" ::= 47 clearLowBattery TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Low battery alarm has been cleared" ::= 48 alarmMainsFailure TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Mains failure alarm has been triggered" ::= 49 clearMainsFailure TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Mains failure alarm has been cleared" ::= 50 alarmDialTone TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Dial tone failure alarm has been triggered" ::= 51 clearDialTone TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Dial tone has been restored. Alarm has been cleared" ::= 52 alarmFaultyAnalogueSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Faulty analogue sensor alarm has been triggered" ::= 53 clearFaultyAnalogueSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Faulty analogue sensor alarm has been cleared" ::= 54 alarmModemInitialisationError TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Modem initialisation caused an error" ::= 55 alarmSimCardError TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. SIM card caused an error" ::= 56 clearSimCardError TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. SIM card error cleared" ::= 57 clearEthernetConnection TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Ethernet Connection error is cleared" ::= 58 clearACVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. AC Voltage sensor sensorID alarm is cleared. Sensor reading is sensorValue" ::= 59 warningHighACVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. AC Voltage sensor sensorID has triggered a high warning. Sensor reading is sensorValue" ::= 60 warningLowACVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. AC Voltage sensor sensorID has triggered a low warning. Sensor reading is sensorValue" ::= 61 alarmHighACVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue} DESCRIPTION "Trap origin is from trapSource. AC Voltage sensor sensorID has triggered a high alarm. Sensor reading is sensorValue" ::= 62 alarmLowACVoltageSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. AC Voltage sensor sensorID has triggered a low alarm. Sensor reading is sensorValue" ::= 63 clearCurrentConsumptionSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, currentConsumption } DESCRIPTION "Trap origin is from trapSource. Current Consumption alarm is cleared. Sensor reading is 'currentConsumption'" ::= 64 warningCurrentConsumptionSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, currentConsumption } DESCRIPTION "Trap origin is from trapSource. Current Consumption has reached warning level. Sensor reading is 'currentConsumption'" ::= 65 alarmCurrentConsumptionSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, currentConsumption } DESCRIPTION "Trap origin is from trapSource. Current Consumption has reached alarm level. Sensor reading is 'currentConsumption'" ::= 66 criticalCurrentConsumptionSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, currentConsumption } DESCRIPTION "Trap origin is from trapSource. Current Consumption has reached critical level. Sensor reading is 'currentConsumption'" ::= 67 shutdownHighTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue} DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID has triggered a high shutdown alarm. Sensor reading is sensorValue" ::= 68 shutdownLowTemperatureSensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Trap origin is from trapSource. Temperature sensor sensorID has triggered a low shutdown alarm. Sensor reading is sensorValue" ::= 69 shutdownHighHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue} DESCRIPTION "Trap origin is from trapSource. Humidity sensor sensorID has triggered a high shutdown alarm. Sensor reading is sensorValue" ::= 70 shutdownLowHumiditySensor TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, sensorID, sensorValue } DESCRIPTION "Humidity sensor sensorID has triggered a low shutdown alarm. Sensor reading is sensorValue" ::= 71 eventGraphsCleared TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Graph data cleared by Administrator' triggered" ::= 100 eventSNMPUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'SNMP settings updated' triggered" ::= 101 eventEmailUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Email settings updated' triggered" ::= 102 eventSensorSettingsUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Sensor settings updated' triggered" ::= 103 eventDeviceRebootSuccessful TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Device reboot successful' occured" ::= 104 eventDefaultsLoad TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Defaults loaded' triggered" ::= 105 eventFlashCorruptionDetection TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Falsh Corruption discovered. Loaded defaults' triggered" ::= 106 eventPasswordUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Password changed' triggered" ::= 107 eventDeviceReset TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Device reset via web interface' triggered" ::= 108 eventTimeDateUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Date/Time updated' triggered" ::= 109 eventDeviceParamsUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Device name/location updated' triggered" ::= 110 eventNetworkParamsUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Network parameters changed' triggered" ::= 111 eventModemUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'SMS/Modem parameters changed' triggered" ::= 112 eventIPMonitoringUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Network monitoring settings changed' triggered" ::= 113 eventRelayUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Relay settings updated' triggered" ::= 114 eventSensorTriggerActionUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Sensor trigger action settings updated' triggered" ::= 115 eventLogCleared TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Alarm and Event log cleared' triggered" ::= 116 eventRelayThermostatOn TRAP-TYPE ENTERPRISE trapControl VARIABLES {trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Relay - Thermostat On' triggered" ::= 117 eventRelayThermostatOff TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Relay - Thermostat Off' triggered" ::= 118 eventCameraUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Camera settings updated' triggered" ::= 119 eventRelayTurnedOn TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Relay turned on' triggered" ::= 120 eventRelayTurnedOff TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Relay turned off' triggered" ::= 121 eventRelayLatchReset TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Relay latch reset' triggered" ::= 122 eventTestSNMP TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Test SNMP Traps' triggered" ::= 123 eventTestSMS TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Test SMS' triggered" ::= 124 eventTestEmail TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Test Email' triggered" ::= 125 eventOutletTurnedOn TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, outletID, outletName } DESCRIPTION "Trap origin is from trapSource. Event 'Outlet Turned On' triggered. Outlet id is denoted by outletID. Outlet name is outletName" ::= 126 eventOutletTurnedOff TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, outletID, outletName } DESCRIPTION "Trap origin is from trapSource. Event 'Outlet Turned Off' triggered. Outlet id is denoted by outletID. Outlet name is outletName" ::= 127 eventOutletTurnedRebooted TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, outletID, outletName } DESCRIPTION "Trap origin is from trapSource. Event 'Outlet Rebooted' triggered. Outlet id is denoted by outletID. Outlet name is outletName" ::= 128 eventGlobalOutletOn TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Global Outlets Turned On' triggered" ::= 129 eventGlobalOutletOff TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Global Outlets Turned Off' triggered" ::= 130 eventGlobalOutletReboot TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Event 'Global Reboot on Outlets' triggered" ::= 131 eventOutletConfigured TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr, outletID } DESCRIPTION "Trap origin is from trapSource. Outlet bearing 'outletID' has been configured" ::= 132 eventCurrentThresholdUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Current Sensor threshold values updated" ::= 133 eventSerialPortParamsUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Serial Port Settings Updated" ::= 134 eventUserParamsUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. User Parameters updated. User names or passwords have been updated" ::= 135 eventAdminUserParamsUpdate TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Administrator User Parameters updated" ::= 136 eventConfigurationLogCleared TRAP-TYPE ENTERPRISE trapControl VARIABLES { trapSource, trapDescr } DESCRIPTION "Trap origin is from trapSource. Configuration Log Cleared" ::= 137 END